BIPit

u/BIPit


r/homelabsales•

I have a dell R630 that I upgraded from. It has these specs

2x Xeon E5-2695 V4 iDRAC 8 Enterprise RAM - 32GB Dual 750W PSUs

Checking Labgopher, it seems between $300 and $400 is current. Is that accurate for this system in this config?

37

r/Proxmox•

Hey all, trying to migrate my ESXI VMs to a new installation of Proxmox. I've updated the server, I'm on version 8.2.2. I have pve-esxi-import-tools installed. When I go to Datacenter > Storage > Add, I don't have any ESXI option.

I've gone over tutorials, the official documentation, other reddti threads but I don't see anyone having this issue. I'm sure I'm missing a simple step here but any help would be appreciated.

23


r/Esphome•

I'm working on building a Godzilla lamp for my kid. All LEDS are currently wired inline. The LEDs are SK6812.

https://preview.redd.it/l2pdwrzesvda1.jpg?width=2389&format=pjpg&auto=webp&v=enabled&s=394cf5ac5130aa6d40a62cd442d66476f41c946a

​

What I'm trying to do is get LEDs 1 - 11 to do a "charge up" effect (e.g. LED#1 turns on, delay, LED#2 turns on, delay, LED#3 turns on) and when LED#11 turns on, there's a short delay, and then LEDS#12-22 in the flame all turn on simultaneously and pulsate. (LEDS#1-11 would remain on).

​

Here is what I have so far, but I'm sure it's a bit of a mess, and I haven't figured out the pulse effect. Should I be using ad

59

r/homelabsales•

A guy I know bought a lot from a business closure auction and in it he found a ton of server equipment. He reached out to me to help but I think I'm in over my head on this one. What's a fair price for a bulk sale of this equipment?

 

What I saw in the racks:

  • 20+ R730XDs
  • A few R720XDs and R720s
  • A lot R710s
  • Ton of supermicro servers (not familiar with them, no clue the specs)
  • misc servers (R220s)
  • Switches/accessories galore
  • most servers had some amount of hard drives (mixed bag of types, some SSDs both enterprise and commercial)
  • over 2500 hard drives new in boxes (mostly 1TB)

 

Hard to inventory everything that was in this lot. It really looked like a s

4843




r/homelab•

Hey everybody,

Recently I was checking on my systems and noticed I had a flashing yellow on one drive and then a flashing green/yellow on another drive. I did all the normal troubleshooting and after checking the connections and re-seating the flashing yellow drive, it came back on line with no error. The flashing green/yellow is still having issues. I wanted to back up everything, replace both disks and rebuild the virtual disk, but when in the BIOS, both disks show up with a "Foreign" flag in physical disk management and I can't get the VD back on line. Is there a way to clear the flags to bring the VD back online so I can backup?

I've also checked Google, but most of solutions don't se

14