Hello all. I have an existing home with a vented attic. There’s loose fill cellulose at the ceiling joists, but also fiberglass bats in the rafters.
Any clue why there would be bats in the rafters for a vented roof? I do unfortunately have a few R-8 insulated hvac ducts in the attic. One insulation company recommended keeping the bats and topping off the ceiling to R-50 (some air sealing from below), and another recommended removing everything, better air sealing from above and just new loose fill insulation for R-49 or 60.
Thanks for any insight. In climate zone 5b.
Hello all. I have an existing home with a vented attic. There’s loose fill cellulose at the ceiling joists, but also fiberglass bats in the rafters.
Any clue why there would be bats in the rafters for a vented roof? I do unfortunately have a few R-8 insulated hvac ducts in the attic. One insulation company recommended keeping the bats and topping off the ceiling to R-50 (some air sealing from below), and another recommended removing everything, better air sealing from above and just new loose fill insulation for R-49 or 60.
Thanks for any insight.
Can someone clarify if I have 200 or 400 amp service? I'm a recent homeowner and I assumed I had 400 amp service until I opened the right side of my meter mains and I'm starting to think I may have 200 amp service.
- Images Here. I'm located in Utah.
- My Meter Mains is a Square D SC816D200C and is mounted on the outside of my home.
- Inside my garage I have two separate 200 amp load panels with all the individual branch circuits.
- The last picture in the above album has the wiring diagram from Schneider on the meter mains.
- As far as I can tell, the meter on the left feeds through the 1/2/3/4 (diagram) on the right (lower 200 amp circuit breaker in the p
Hello all,
I'm trying to find a way to automate adding a 5.1 channel audio stream to a file if only a 7.1 channel stream exists.
I've figured out how a to add a 5.1 channel audio stream to a 7.1 only file, but I can't figure out how to automate it by adding a filter to check if a 7.1 channel stream exists without a 5.1 channel stream.
The "Filter by file property" filter only looks at top level properties which doesn't look to include the channel information.
I've also tried the "Filter by stream tag" using a tagName of "channels" and a tagValue of "8" but haven't had any luck with this either. Am I messing up on the syntax?
Thanks for any suggestions!
Short and sweet: I wanted to know how much power a smart plug uses when idling so I checked with a multimeter. I checked two plugs in both the switch on and switch off states. Both plugs used more power when switched on which makes me think they are "normally off" relays.
| . | Idle Off (W) | Idle On (W) |
|---|---|---|
| Zooz Zwave+ w/ energy monitoring (ZEN04) | 0.2W | 1W |
| Kasa Wifi w/o energy monitoring (HS103) | 0.17W | 0.6W |
Ignoring other power draws, you can run around 50 smart plugs and only use 10 watts at idle which makes me feel pretty good.
A short while ago I posted some fan configuration results here. I read through the replies and changed my setup outside of the fans a bit and got noticeably better results. I simply lifted my computer ~1 inch off the ground and moved my UPS to not be right next to my computer which improved airlow. Here are the simplified results:
| T in °C | Config 1 | Config 2 | Config 3 | Config 4 | Config 5 | Config 1 (2nd run) |
|---|---|---|---|---|---|---|
| Adjacent Ambient | 22 | 23 | 23 | 22 | 23 | 23 |
| Mobo | 39 | 42 | 45 | 43 | 43 | 37 |
| Chipset | 49 | 52 | 53 | 51 | 54 | 47 |
| Ram | 43 | 45 | 47 | 45 | 50 | 39 |
| NVME | 37 | 41 | 4 |
Hello r/watercooling, I spent several hours testing four fan configurations on my build and thought I'd share my results.
To start: My Desk Setup. I'm space limited in an apartment with shared side-by-side desks. My computer has to live on the floor and the desk traps heat a bit. To combat this, I did three things which kept the temperature around the computer stable:
- I had a fan (pic linked above) blowing fresh air under my desk.
- I had a fan (pic linked below) blowing hot air from under my desk out towards the door.
- I had my central HVAC fan blowing constantly and set to 70F (21C).
My rig is pictured here (sorr
Hello all, quick question about the EK RMA / return process. I bought a VTX pump from their web store which ended up considerably louder than a ddc, making an odd clicking/rubbing noise and vibrating significantly. I started a return through EK and purchased a replacement EK DDC pump combo (stateside) because I didn’t want to wait through the RMA. The replacement EK DDC that came is great, no vibrations and normal noise levels. The only oddity to me is that the pump cables aren’t sleeved (vtx was).
Anyway, EK finally got back to me and wants me to do the following:
“What I suggest is that you disassemble the pump motor from the unit and remove the impeller. Check if there is any dirt prese