thetimes.com/world/europe/article/man-stabs-w...Is there a way of getting the OFFICIAL Microsoft office app on the A1? The one that comes with the device isn't the official one (version and signature do not match) and most importantly doesn't supports Intune device management which means it's utterly useless for any real productivity since it would never be able to connect to anything other than outlook.com which is basically Hotmail.
I know this is a Chinese device, but come on, I didn't expect the most basic productivity features to not work on it.
Any one got a source for the file?
Thanks
The U1 uses an inductive probe through the nozzle for sensing the bed.
I've noticed that with the default settings there is a variance of +-0.2 and sometimes even more which is why the default probe tolerance is set at 0.2.
This makes high probe count passes fail because you reach the threshold allowance rather fast and or if you increase the allowance the probing takes ages.
This is also why the green line is jittery when you are doing the manual bed leveling.
I found that reducing the relative_trigger_freq from the default value 300 improves the consistency of the inductive probe.
I've validated that this doesn't impact actual mechanical accuracy, with dimensional shim stock.