Hey yall,
Anyone else have automations refusing to finish again? Same thing that happened a few months ago, it appears to have started (pun intended) on the 20th, everything after that has never finished.
No jobs have been changed.
u/ShadowCVL
Hey yall,
Anyone else have automations refusing to finish again? Same thing that happened a few months ago, it appears to have started (pun intended) on the 20th, everything after that has never finished.
No jobs have been changed.
This is driving me batty and I am really not sure whats going on.
So I have a Creator 5 Pro
Im trying to print with some wood PLA
It needs to print around 210 for first layer and 205 for the remaining layers or it gets stringy (ive verified this on my other creality printers)
So, in The FlashForge slicer (latest version, latest firmware on printer) I created a wood pla profile, set the min temp to 190 and max to 210, loaded the filament in the printer with a pla profile. I also set the aux cooling fan to 50% as 70 is causing it to cool way too fast
Slice it up in the slicer, and send it to the printer. Printer (after its painfully long startup) jumps to 220 and 70% on the aux fan.
Hey fellow taxpayers and taxpreppers,
Met with my CPA today to get everything going and have run into a little bit of a weird roadblock. My google-fu and Lake draining AI usage have given me opposing answers so I need a little help, hopefully someone can get the info I need.
So, last year we renovated a house and put in a new geothermal heat pump, heat pump water heater, and 2 battery backup systems for the house. My CPA asked me for the QMID for the 3 manufacturers.
Carrier Geo, no problem
Bradford White, no problem
Anker Solix, heres the problem. On their website, [https://www.ankersolix.com/blogs/solar/residential-clean-energy-credit](https://www.ankersolix.com/blogs/s
So, I'm going to detail my journey, I "think" its Sciatica, but its not responding to literally anything.
2+ years ago I was put on statins for cholesterol (early 40s Male) they cause pain in my upper legs and calves, mostly the right calf. This happened at the exact time I started taking them, despite my doctor saying it only affects upper legs. Stopped those, pain went away, tried another, pain returned, stopped those pain never went away. Relieving the pain was simple, 2 ibuprofen before bed or soak lower legs in hot water (hot tub, bath, etc). No big deal, then a year or so ago I realized the pain would show up (I was back on a different statin but it hadnt caused any real issues
Hey folks, got a new one that I cant seem to get rid of. Its driving me insane.
So my setup at both of my houses (long story, will be 1 by end of year) is a UDMSE, city's fiber as primary, tmobile as secondary.
Until about a month ago its been seamless. I even replicate my NAS between these networks every night.
But, now whenever I have ANYTHING using more than a few megabit for more than a few minutes I start getting "wan 1 failed over" "wan 1 recovered" "wan 1 has failed multiple times in the last 24 hours". This is happening at both sites without fail. Start a game update, failover, stream a movie, failover.
But thats the thing, it doesnt actually fail over, connections es
Anyone else having a weird issue the last week? I have 2 x30s and they both do the same thing, go to the room that I tell them to clean, clean, then when they try to go to the dock the will just spin, move a foot, spin, etc until I’ve realized they have now covered the entire room in spin marks. It’ll even do it within line of sight of the dock.
Hey folks,
you probably remember my weekend dumb question about split 400amp service. Had the electrician out today, they are installing 2 transfer panels with 50 amp inlets.
Heres where I feel ultra stupid.
Shopping for generators and battery banks most of them have an L14-30 and say they are rated for 30 amps 240 or 6000 (or more watts). Well Im only going to be running 120v circuits. Last time I did the math 6000 watts is 50 amps at 120. SO, do I just grab an adapter from L14-30 to 14-50 and call it a day or am I missing something utterly stupid?
If the generator can put out 6000 watts at 240, doesnt that mean it can put out 3000 watts per leg of hot at 120?
Exampl
Quick question for any one who has a new UNAS Pro 8...
Is there anywhere to see the power supply status? I installed the redundant PSU today (it arrived a week later than the NAS itself), it lit up green and I can see its pulling 40 watts on each outlet of the PDU (temporarily on the same PDU, building out new location), but I cant find a spot in the UI of the unit nor on the unifi.ui.com dashboard.
Hey folks, if I need to post this to ask electricians let me know.
New house has 400 amp service, split across 2 panels each with Square D 200 amp main breakers. Grounds are bonded, each panel the ground and neutral are bonded (first means of disconnect for each (they are inside a garage, meter is on the outside wall of said garage))
I would prefer to do interlocks with 50 amp inlets if possible
One panel is mostly your plugs and lighting loads with the exception of 1 water heater and the dryer, 50 amps could run that entire panel if I turn the water heater off (actually replacing it with a heat pump version soon so I may just be able to switch it to HP only mode and carry on, but
Hey folks, Im in a bit of a conundrum about how I am going to approach an upcoming move. Watching Clay's video on the unas he mentioned taking it with him on a trip or something like that and it made me start thinking.
The set up: I am moving into a newly renovated house in a few months, at the same time I am going to be moving away from my unraid setup with VMs and to just a nas with a physical plex server and thats about all i need. No sense in building a new unraid box (existing one was built pre-pandemic). Originally I was going to buy a UNAS, set it up at new house and just redirect my backup copies over my site to site but would have to tamp down the bandwidth. Alternatively m
Hey folks, Im out over my skiis currently and need some advice from folks who may have had to deal with a similar situation.
Im completely befuddled, and Ill try to summarize as best I can.
My parents and I built the house with these units in 1997, one of the original units died and was replaced in 2018 or 2019, the other unit (for the basement) is an old addison 2.5ton
The ground loop seems to be in good condition, the current HVAC company adds a few squirts of water each year.
3 years ago I had to start taking over all the day to day stuff for my dad as he had dementia and had let a lot of things slide. Well, in April I inherited the place officially and am trying to get ever
Hey, so I just wanted to ask the experts their opinion on what is going on this year here in Kentucky. We are having one of the wettest years on record (actually almost hit our yearly average already) and until 2 weeks ago I had never seen a termite in real life. We have Eastern Subterranean and thank goodness they are very slow. I found a swarm near my back patio (outside) at my normal house 2 weeks ago, they came and treated the foundation and such yesterday. Well I inherited my parents farm where we built a house in the late 90s and have been taking care of the house itself since about 2014 when my dad just kinda stopped, remodeling it now and haven’t found any damage inside but toda
Hey folks,
I know ubiquiti no longer makes the solar devices, so I need to create a bit of a mesh-ish system at my farm.
Basically the barn has power but it’s only on when you need lights or to charge the tractor battery, due to its infrequent use I haven’t seen fit to update the power panel from a very old pushmatic panel.
I would like to get WiFi to the barn, and down by the road (for cameras).
Not a huge power requirement, I’m thinking building to building bridges and a couple of outdoor APs will handle all I need.
Where I’m coming up short is an easy step by step on deploying a solar panel (or 2), what kind and type of batteries, and all the connections to power 2-4 poe devices, not
Hey folks, does anyone in the US know of a dehumidifier that has a tank level sensor or a full tank warning that works with IoT and Home Assistant?
I have a room in a basement that is sort of external to the foundation of the house, if you want the full story Ill tell it, but it has 4 concrete walls and a concrete ceiling. There is power into the room but no drain and no good way to get a pipe back out of the room to empty a dehumidifier. The room stays more humid than the rest of the basement as it has supply air but no return. This room is obviously perfect for storing valuables and wireless hole punches. I would like to add a dehumidifier that has some connectivity, preferably wit