Hi all, Im going to be dropping a couple 5 ton units into a pit, outside my home. I'll need to core drill, or another method, one or two holes through the basement wall of my mechanical room, to feed lines to the units.
Ive been pondering two 2" holes, to keep temperature transfer between the lines minimal. You guys think that's prudent? Or just one slightly larger hole? I know this is kind of a stupid question. Just thought Id run it by some other knowledgeable people. Thanks.

16

r/Plumbing•

Hello all,

I just did some water tests on an old well that I got back into service. Was waiting to test untill everything had been working and established for a few months. New pump/tank/supply lines, etc.

Anyhow, as I feared. The water has a high level of Nitrates. Everything else is pretty decent. I kind of expected this, due to being in the middle of farm country, with all the years of agricultural runoff.

When I re-plumbed the building, I installed a set of the three 20" big blue canisters, with two sediment, and a carbon, that came with the kit. Also installed a large UV sterilizer.

I was looking at some of the reverse osmosis systems on ebay, but they almost seemed to include

10

r/Plumbing•

Hi all,

I don't know much about urinal flush valves, but I have a couple old Chinal urinals I would like to get back into working order. They have Sloan STAR valves on them. I debated on restoring them, but rebuilding and rechroming these old valves is just out of the budget currently.

Here is what I'm working on: https://i.imgur.com/Bpfgxh7.jpg https://i.imgur.com/JuueNYc.jpg

I looked at some American Standard retrofit valves, Zurn Metroflush, and also some Sloan Regal's. One thing I haven't came across is a template or layout. Is there a standard that is usually followed deciding the pipe stub location in the wall? Should newer valves just fit right up? Anyone know how many GPF thes

36

r/HVAC•

Hello all. I'm turning an old school into a home, and don't really want to doink up the yard with a/c units, nor do I want them up on my roof.

The utility room is in the basement, so I was debating digging a pit, laying foundation/walls, and dropping the units down in that. Piping underground across to the utility room. I can build a raised steel grated floor which the units could sit on, draining rainwater to the sump, and then a grate across the top, so people don't fall in.

Anyhow, the units are 36"x36". How much space would you recommend around them for maintenance when needed, and how far apart would you place them away from each other?

I have some idea, but also a little con

09


r/Plumbing•

Hello all,

I purchased an abandoned school to turn into a home, and am having some issues with deciding how to run the water heater setup, was hoping to get some advice from people smarter than I.

Here is an image of the general pipe layout of the building. I mocked it up in 3ds Max, but admittedly didn't get too crazy on the details. The building is 60ft wide, and 50ft deep.

https://i.imgur.com/WkFxH7R.png

  • Dark blue is cold 1.5"
  • Middle blue is cold 1"
  • Light blue is cold 3/4"
  • Red is hot 3/4"
  • Yellow is power in from pole
  • Red box is current hot water heater
  • Bright green is three Big blue 20 filters
  • Aqua green is a UV sterilizer

I have a 1.5 HP pump 90Ft deep outs

20