danielbot

u/danielbot


r/OrcaSlicer•

Hi all! First off, hello, and bountiful thanks for the great tool! Went from complete 3D printing newbie to defining solid scarf joints for internal bolt bosses in about an hour. Let's get straight to the whining.

Here is how I start orcaslicer on debian sid:

sed -i 's/"language": *"[^"]*"/"language": ""/g' ~/.config/OrcaSlicer/OrcaSlicer.conf && ./OrcaSlicer_Linux_AppImage_Ubuntu2404_nightly.AppImage

Without the sed, it bails with "Switching Orca Slicer to language en_US failed". It also doesn't remember the "remember this setting" on the startup certificate nag when it bails.

10

r/u_danielbot•

https://preview.redd.it/i3xhg485dqrh1.png?width=1920&format=png&auto=webp&s=0c0dbd3db290f3ac5263f005f9fcd3796914f38c

Bolts - how hard can they be? Well, in my experience, adding fasteners to a model can be, how shall we say, a minefield of fragility and model bloat. I would like to share a couple of techniques that are working pretty well for me. I could share a grab bag of attempts that didn't work so well, but you probably know about that already from your own character building experiences.

First we need some bolts, and we need then in various sizes. That's where things can go pear shaped very quickly. I could have just gone with the flow and installed the fasteners workbench. But it lo

10

r/FreeCAD•

Creative Sketching

Just thought I would drop this in-progress screenshot. A great deal of engineering process is now under the bridge. Model evolution is now mostly concerned with dividing this fanciful structure up into parts that can realistically be printed.

The translucent green steampunk motor housing is now factored into three pieces that can be printed with no overhangs anywhere that needs to be dimensionally stable. Just that one rectangular access hole... needs a bit of care and attention to avoid sagging there. It wouldn't hurt structurally, just look ugly and w

51

r/FreeCAD•

The worst thing about my sailboat is, no autohelm, adding considerable challenge to single handing. Correcting this is no small task. While you can buy various solutions from big name vendors, these understandably come without mounts. Fabricating a mount will probably cost several times the price of the unit. I also have concerns about durability of these units in heavy weather, and the likelihood of lock-in with other gear from the same vendor. So I decided to take a run at engineering one of my own. I went with a wheel autohelm scheme:

Wheel Autohelm

Inside the motor ho

30

r/Homebuilding•

This is a followup to my earlier post asking whether it is optional to ventilate my upcoming standing seam roof. Among the excellent threads under that post I learned the concept of hot roof, and that yes, venting a residential roof is indeed optional, both from a (local) regulatory and practical point of view. BUT is it a good idea to skip the ventilation? I think not.

I also think that the way the relevant BCBC regulation is written is, in a word, nonsensical, flying in the face of energy efficiency as it does. The only actual sensible part of it is the "except where it can be shown to be unn

10

r/Homebuilding•

I am an owner/builder and I am only part way through the process of everything I need to learn to manage my upcoming laneway house project, or ADU as we say here in BC. I am in the middle of designing my roof system and I am going to make a bunch of mistakes, so please bear with me.

The immediate issue is that I am mystified by the following provision of the BC building code:

9.19.1.1. Required Venting

  1. Except where it can be shown to be unnecessary, where insulation is installed between a ceiling and the underside of the roof sheathing, a space shall be provided between the insulation and the sheathing, and vents shall be
    installed to permit the transfer of moisture from the spac
646

r/Homebuilding•

See, there are two big holes where sidelights should go:

Laneway House With Missing Sidelights

My problem is, I don't want to put a complete double door plus sidelights structure for a couple of reasons. The outrageous price is a factor but not the main factor. I just want a nice solid double steel door there with 4x4 doorposts, and I want to build the sidelights essentially as separate fixed windows. Simple idea, right? But try to find 80x14 inch triple glazed glass. It's just not out there for normal people. Window factories can get it, but I can't, or at least I don't

18

r/FreeCAD•

2D is the future for Laneway House modeling... because 2D drawings are how you get building permits. No room for debate there. So accordingly, I rolled up my sleeves and dove into Techdraw.

Earlier I played around a bit and tried to just wave my hands and magically get a set of Laneway House architectural drawings. No such luck. If you have played around with techdraw then you know why. I'm not going to go into detail. So... back up, try again with something a bit less ambitious. This time, my basement suite kitchen model. Here is how it looks with doors:

[Laneway House Kitchen with Doors](https://preview.redd.it/iqek68jo189f1.png?width=1920&format=png&auto=webp&s=c6954bc1e7dcf62d28079da6a

2018


r/FreeCAD•

That is, getting its stale air Exhausted. That's the rule these days... you have to have a plan to exhaust your stale air or you can't build your house.

I am now preparing ready to put my HVAC design out for quotes. The essential thing is to be able to communicate the design concepts efficiently so that the pros know exactly what they're looking at and exactly what I want. Then they will be able to comment, firstly, on whether it makes sense, and secondly (arguably more import) how much it will cost. There's also a remote possibility they will ask me to make changes.

Just kidding, it's a practical certainty. Here is my concept, it's a hybrid HVAC/Ventilation system:

[Laneway House Hybrid

136

r/FreeCAD•

Laneway house getting exhausted

That is, getting its stale air Exhausted. That's the rule these days... you have to have a plan to exhaust your stale air or you can't build your house.

I am now preparing ready to put my HVAC design out for quotes. The essential thing is to be able to communicate the design concepts efficiently so that the pros know exactly what they're looking at and exactly what I want. Then they will be able to comment, firstly, on whether it makes sense, and secondly (arguably more import) how much it will cost. There's also a remote possibility they will ask me to make changes.

Just kidding, it's a practical certainty. Here is my concept, it's a hybrid HVAC/Ventil

10

r/FreeCAD•

I've had a number of comments over the last few months to the effect that I will never be able to build my little Laneway House with four inch floors. Oh ye of little faith! With the help of FreeCAD, I tackled the structural engineering problems and found a way to make it work. This includes documenting the design analysis so that I can prove it works, with cold, hard numbers. In construction-speak, I will rely partly on Part 4 engineering analysis instead of Part 9 prescriptive rules, which is explicitly allowed by the building code. It is up me to get engineering signoff for my Part 4 design elements, and that comes down to whether my math is right. I think it is, but we shall see.

Now I

21

r/FreeCAD•

Here is my tentative solution to a structural problem I have had simmering on the back burning for quite some time:

Thin beams for a Thin Floor

These nice blue beams are supposed to solve the problem of how to make my thin 4 inch floors stiff enough to meet building code. The trouble with me as an architect is, I don't know what I can't do, so I decided that my little Laneway House has to have two standard height upper floors plus a four and a half foot attic all within the 6.5 meter zone height limit. This leaves me with four inches each for the main and loft floors.

101

r/AskEngineers•

Hi, I created a problem for myself that I would like to solve in an elegant way. I am designing a laneway house. This is my first attempt at architectural design, so I don't know much, but I do have the habit of digging deeply into problems as I encounter them. I want my structure to have 2x4 walls and floors. Building code does not prohibit this, but practical considerations make it difficult. One major problem is that it is hard to make the floors stiff enough.

My plan is to use short 2x4 joists laid between sturdy beams, so that the 2x4 spans comply with the prescriptive residential code (BC Building Code Part 9). When it comes to beams, BCBC says they need to be engineered and signed of

28