It's time for my church to get some new livestreaming cameras, and I haven't been in the market for a while, so I'm curious to know what others are using. This will be a set of three cameras operated from a single position, so they need to be remote PTZ capable.
etcpt
u/etcpt
It's time for my church to get some new livestreaming cameras, and I haven't been in the market for a while, so I'm curious to know what others are using. This will be a set of three cameras operated from a single position, so they need to be remote PTZ capable.
I think I have all the terms right, but I'm still new to the admin side of Google Workspace, so thanks for bearing with me.
I currently have a business account with one seat of Google Workspace Business Standard for an organization that is eligible for Google for Nonprofits. We have activated Google for Nonprofits and are in the process of using that to activate Google Workspace options. The dialog for that process tells me that I can't go straight from Google Workspace Business Standard to Google Workspace for Nonprofits, I can either continue to use Google Workspace Business Standard at Google for Nonprofits discounted pricing, or downgrade to Google Workspace Business Starter and then tr
I have an Agilent G4290 "all-in-one" HPLC-UV for the lab I am teaching. The autosampler has kicked the bucket and is throwing a fatal error about the motor being overtemp. I don't have time or funds to get that fixed right now, but I do have a manual valve. So I plumbed that together and it's working fine, but when I go and try to run a sample, with the method set to use a manual injector, it gives me a "not ready wait" condition after submitting the run. I'm assuming this is due to the AS being not ready, and since it's an integrated module I can't do what I did the last time I had this problem and just remove it from the configuration in ChemStation.
Hoping that someone might have experie
I have an Agilent G4290 "all-in-one" HPLC-UV for the lab I am teaching. The autosampler has kicked the bucket and is throwing a fatal error about the motor being overtemp. I don't have time or funds to get that fixed right now, but I do have a manual valve. So I plumbed that together and it's working fine, but when I go and try to run a sample, with the method set to use a manual injector, it gives me a "not ready wait" condition after submitting the run. I'm assuming this is due to the AS being not ready, and since it's an integrated module I can't do what I did the last time I had this problem and just remove it from the configuration in ChemStation.
Hoping that someone might have experie
I have an Agilent G4290 "all-in-one" HPLC-UV for the lab I am teaching. The autosampler has kicked the bucket and is throwing a fatal error about the motor being overtemp. I don't have time or funds to get that fixed right now, but I do have a manual valve. So I plumbed that together and it's working fine, but when I go and try to run a sample, with the method set to use a manual injector, it gives me a "not ready wait" condition after submitting the run. I'm assuming this is due to the AS being not ready, and since it's an integrated module I can't do what I did the last time I had this problem and just remove it from the configuration in ChemStation.
Hoping that someone might have experie
Has anyone ever tried to "ash" a sep funnel (heat it to 350+ C) to remove TOC before using it in an analysis? I'm a bit worried that the stopcock seat or its connection to the body might break, and my colleague is worried that it might deform enough that the stopcock won't fit after heating/cooling (based on being taught over and over to not heat analytical glassware because it may deform and no longer be accurate, but we're not sure how serious that deformation can be). Hoping that someone might have done this before and have some idea of feasibility.
N.S. probe into pharma worker's death finds vent hoods turned off in lab
saltwire.com/atlantic-canada/federal-election...A friend of mine, who is an engineer, is starting a project which involves handing gram-scale quantities of PFAS, as well as contaminated environmental samples. They asked me for advice on laboratory safety, and I walked them through some of the basics (fume hood use being preferable to masks, use of splash goggles over safety glasses for large solution volumes, etc.), but I realized that I haven't really seen a comprehensive guide to the hazards and safe handling practices for PFAS. What I've read online seems to indicate that the standard practices we'd follow for toxic and/or carcinogenic compounds are sufficient, but I can't shake the feeling that I'm missing something.
I'm hoping some
I've seen several posts on here where folks have shared their TBs for others to discover and gotten a positive response, so I thought I'd pass on this one that came up in the Snag the Tag group. Black Hat was the rarest coin from the recently completed No More Secrets game, and this finder made a cool little video to show off their unboxing. Give it a watch and discover a cool trackable! (Not my video, FWIW.)
Hello math friends,
I recently came across the hypergeometric distribution as a possible answer to a question which came up in the course of my PhD research (bioanalytical chemistry). I've been reading online resources and lecture notes, and I think I'm getting a good grasp on the application, but I would like to delve a little more deeply into the fundamentals to get a better understanding. I've been looking around for texts on this topic (including the book recommendation threads here and on r/math) and so far the only thing I've really hit on was finding a text called Generalized hypergeometric functions with applications in statistics and physical sciences by Mathai and Saxena (1973),

