Hi all,
Two NX-OS 9000v leafs in vPC via Fabric Peering (virtual peer-link over VXLAN), downstream IOS switch dual-homed via one LACP port-channel. Every ~90s the downstream port-channel err-disables (channel-misconfig (STP)), recovers, repeats.
vPC health, consistency-parameters, LACP mode, STP bridge-id, MTU, CoPP — all clean.
debug lacp all on the leaf shows why: partner LACPDUs arrive every ~1s but get dropped before reaching the interface's state machine, resolved against the wrong if_index
if_index = 0x1a000400 (real one is 0x1a000800)
port_enabled=0
Receive pkt failed
90s later → LACP long-timeout → LACP_ST_SUSPENDED_FOR_MISCONFIGURATION → err-disable dow